The circuit breaker has the characteristics of small size, light weight, anti-condensation, maintenance-free, etc., and can adapt to harsh weather conditions and dirty environments.
Contact Now
The overall structure of this product adopts a three-phase common box type, the bushing enters and exits the line, the box is filled with dry air, and the electric spring fan operating mechanism is arranged on the side of the box, which can be used reliably under severe environmental conditions. The vacuum interrupter of this product adopts ceramic shell, cup-shaped longitudinal magnetic field contact structure, copper chromium contact material, and has excellent breaking and closing short-circuit current capacity. The product is small in size, light in
Contact Now
The circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body, which can be used as a fixed installation unit or equipped with a special propulsion mechanism to form a handcart unit.Model and meaning This type of product is equipped with a bistable permanent magnet operating mechanism. The mechanism is equipped with a permanent magnet. The permanent magnet provides the holding force to keep the switch in the closed and open state.
Contact Now
GN30-12 rotary indoor high-voltage disconnector is a new type of rotary contact disconnector. Its main structure is to fix two groups of insulators and contacts on the upper and lower planes of the three-phase common chassis, and to achieve switch on by rotating the contact.The GN30-12D switch is an additional form with grounding knife on the basis of the GN30-12 switch, which can meet the needs of different power systems. This product is compact in design, small in point space, strong in insulation capacity, and easy to install and adjust.
Contact Now
It is mainly used to break and close the load current, overload current and short-circuit current of the power system. It is suitable for protection and control of substations, industrial and mining enterprises, and urban and rural distribution networks, especially for places with frequent operations and urban automatic distribution networks. This product is matched with the controller, which can meet the requirements of the distribution automation system, and can reliably and effectively complete the traditional recloser function.
Contact Now
normal use conditionsAmbient air temperature: upper limit +40°C lower limit -25°CAltitude below 2000mRelative humidity: the daily average value is not greater than 95%, the monthly average value is not greater than 90%The surrounding air should be free from obvious pollution such as corrosive or flammable gas, water vapor, etc. No frequent violent vibration
Contact Now
FN12-12 and FN12-12R combined apparatus are three-phase high-voltage switchgear with a rated voltage of 12KV and a rated frequency of 50Hz. They are used for breaking and closing load current, closed-loop current, no-load transformer and cable charging current, closing short circuit current, and load switches equipped with grounding switches.
Contact Now
The role of drop-out fuses10kV equipment can be installed on the high-voltage side of the transformer on the pole, where the transformer and capacitor are connected to the line. The drop-out fuse can effectively protect the circuit from overload and short-circuit. At the same time, it can also be installed at the end of a long line or on a branch line, which can provide extended protection for areas that cannot be protected by relays.
Contact Now
The main function Vacuum arc extinguishing is adopted, with strong breaking capacity, long electrical life and mechanical life of 10,000 times; Simple structure, maintenance-free, no long maintenance period; Good insulation performance, strong anti-pollution ability; Equipped with spring or electromagnetic operating mechanism, the mechanical performance is reliable and can be operated frequently; No fire and explosion hazards; built-in current transformer, the accuracy reaches 0.2 level, and can real
Contact Now
FGW9-12 high-voltage load disconnector is a high-performance disconnector developed by our company by absorbing foreign advanced technology. It has the advantages of reliable contact, large current carrying capacity, and certain arc protection capability. It is used in the power system with the rated voltage of 10kV to connect and isolate the power supply when there is voltage.
Contact Now
Product OverviewGW1-12G (D) series outdoor high-voltage disconnectors are unipolar high-voltage switchgear. They are used to open and close the circuit when there is voltage or no load in the outdoor 12KV line network. The switches with grounding knives are equipped with CS mouth type manual mechanisms to prevent the misoperation of live grounding wires and grounding wires, "closing", etc.
Contact Now
The performance of JN15-12 household air high-voltage grounding switch meets the requirements of GB1985-89 AC High Voltage Disconnectors and Grounding Switches and IEC129, and is applicable to 12kV and below AC 50Hz power systems. It can be used together with various types of high-voltage switch cabinets as grounding protection.Advanced design and reliable technical performance; Simple structure, convenient installation and debugging; Have the ability of quick opening and closing.□ Operating environment1. The altitude shall not exceed 1000m;2.
Contact Now
Y. F series porcelain clad arrestersummaryThe arrester is the basis for insulation coordination of various electrical equipment (transformer, reactor, capacitor, engine, motor, PT, CT, circuit breaker, contactor, etc.) in the power system.
Contact Now
ZFN21-12D/630-20, ZFN21-12DR/T125-31.5 high-voltage vacuum load switch and combination apparatus are used in three-phase AC 10KV, 50Hz power distribution system. It has the advantages of compact structure, small volume, light weight, long service life, strong making and breaking capacity, safety and reliability, etc.
Contact Now
GW4 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
GW9-10 outdoor high-voltage disconnector is a single-phase AC 50HZ high-voltage switchgear, which is used in the power system with the rated voltage of 10KV to connect or disconnect the power supply with voltage and without load.The disconnector is operated with insulating rod.□ Operating environmenta. Altitude not exceeding 1000mb. Ambient air temperature: upper limit+40 ° C, lower limit - 30 ° C in general areas, and - 40 ° C in alpine areasc. Wind pressure shall not exceed 700Pa (equivalent to wind speed of 34m/s)D. Seismic intensity shall not exceed 8 degreesE.
Contact Now
(H) GW4 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
(H) GW5 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
summaryAs a special accessory of the arrester, the disconnector is used in series with the arrester. The purpose is to use power frequency short circuit current to make the disconnector act when the arrester is abnormal and fails, so that the grounding terminal of the disconnector can be automatically disconnected, and the arrester can be withdrawn from operation to prevent further expansion of the accident.
Contact Now
Capacitive HY5WR surge arrester is used in 6KV lines to prevent overvoltage generated by vacuum switch and oil-less switch operation capacitor bank, protect capacitor bank from overvoltage damage and absorb overvoltage energy.Advantages of H05WR-10/27 capacitive mine injectorHY5WR-10/27 Capacitor Harm Avoidance Device has good volt-ampere characteristics, excellent protection performance and impact response characteristics, high tolerance to multiple lightning and overvoltage performance, good pollution resistance and other advantages, and the structure Simple, HY5WR-10/27 capacitive arrester
Contact Now
Three phase combined zinc oxide arrester with composite sheath is a new type of protective appliance used to protect the insulation of power equipment from over-voltage hazards. It effectively limits the over-voltage between phases while limiting the over-voltage between phases and ground. It is widely used to protect vacuum switches, rotating motors, parallel compensation capacitors, power plants, substations, etc. This kind of combined arrester has been used for more than ten years, and the practice has proved that it is a practical and effective measure to limit the interphase overvoltage.
Contact Now
(H) GW13 type neutral point disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing the neutral point connection of transformer without load. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.□ Structure1. Single pole V-shaped double post rotary structure, with small floor area, mainly consists of base, post insulator, conductive circuit, operating mechanism, etc.2.
Contact Now
Distribution ArresterProduct use conditions:a) Suitable for indoor and outdoor use;b) Ambient temperature -40°C~+40°C;c) The altitude does not exceed 3000m (the porcelain sleeve type does not exceed 1000m);d) The power frequency is not less than 48Hz and not more than 62 Hz;e) The long-term power frequency voltage applied between the arrester terminals does not exceed the continuous operating voltage of the arrester;f) Areas with an earthquake intensity of 8 degrees or below;g) The maximum wind speed shall not exceed 35m/s. Product Model Description:According to JB/T 8459-1996 "Surge
Contact Now
Low-voltage cable lines are widely used in low-voltage power distribution systems because of their reliable operation, lack of poles, lack of ground occupation, lack of unsightliness, and less influence from the outside world.ApplicationFixed indoor, outdoor and underground installations.StandardsHD 603-5D SI, IEC 60502-1,IEC 60332-1 Cat. B.
Contact Now