A range of Trailer mounted Cable Pulling Winches required for the installation of Power Cables where high
pulling tensions are required.
All of the units are designed with the operator in mind. Simple in operation and robustly engineered, these units
are fitted with heavy duty diesel engines powering hydraulic transmission for smooth controlled pulling, and are
fitted with a console mounted line tension indicator so that at all times the operator has a visual display of the
pulling force applied.
Contact Now
X4 UAV miniaturized thermal imager is a small thermal imager specially designed for UAV. It has the characteristics of light weight, small volume, low power consumption, strong environmental adaptability and simple operation. The lens of the product is designed by optical passive heat difference elimination technology. It works in an ultra wide temperature range of - 40 ℃ ~ 55 ℃ without focusing, and can adapt to different areas and indoor and outdoor environments.
Contact Now
The single tube monocular helmet night vision lens has the characteristics of clear imaging, good concealment, light structure and low power consumption. It can be held or installed on the head cap. The product is suitable for patrol, driving, medical aid, observation, monitoring and reading at night or in low illumination environment.
Contact Now
Designed and supplied specifically for "Off Road Use", these Site trailers are all fitted with some form of brake system, hand parking facility and basic vehicle lights. Although not built to conform with EEC braking/lighting directives certain Non EEC countries have operated these units on the highway under the proviso that Towing speeds indicated must not be exceeded at full rated payload.
Contact Now
This unit has been specifically designed to meet the needs of contractors where the necessiiy or the ability to have a Cable Drum Trailer is simply not practical.Available with either a fixed spindle (shown), i.e. drum loaded by external means, or supplied self sufficient in lifting and lowering as used on standard Cable Drum Trailers in our range.The unit comes with a range of options to suit most applications for both the Utility and Rail industries.Diesel, Petrol, Electric or PTO Drum Drive system for ease of cable payout, unit can be pendant controlled.
Contact Now
The coupling between the glass lead rod and the fixture adopts the most advanced crimping technology, with beautiful appearance, small volume, light weight, not easy to break, bending, high torsional strength, strong explosion-proof, and extremely convenient transportation and installation.Type ofinsulator acc.RussianstandardUltimateMechanicalStrength ofinsulators,KN, not lessDiameterof glassshed (D),mmSpacing,mmCreepagedistance,mmWeight, kgVoltage withstand, kV, not lessImpulseFrequency50 Hz, wetRadiointerference levelSHS-10D12,51301602801,35754040SHS-20G131401904001,71355050
Contact Now
Fuse selection The selection of the fuse should ensure that the distribution transformer internal or the high and low voltage outlet pipe can be quickly fused when there is a short circuit. In practice, the following principles are often used for selection; if the capacity of the distribution transformer is below 160KV, the fuse should be 2-2% of the rated current of the transformer.
Contact Now
High temperature control precision and high resolution; High emissivity; Short temperature stabilization time; Low price; Easy to use or integrate.
Contact Now
wire galloping has brought immeasurable economic losses and social impacts to our country. The composite interphase spacer is a kind of line that can effectively prevent the galloping of line conductors to keep the line safe, and effectively reduce the space of the transmission corridor. It is listed as a compact high-voltage transmission line 2220kV and below in the guidelines for galloping prevention and control of the State Grid Corporation of China.
Contact Now
Due to electromagnetic induction, the metal shielding layer (or metal sheath) of long line high-voltage single core power cables generates induced voltage, which leads to aging of insulation and reduction of insulation grade, resulting in reduced cable life. Once the induced voltage exceeds the sheath breakdown voltage, the outer sheath is broken down, forming a multi-point grounding fault of single core cables.
Contact Now
JN22-40.5/31.5 indoor high-voltage grounding switch (hereinafter referred to as grounding switch) is an advanced product with high technical parameters and performance developed by Xi'an High Voltage Apparatus Research Institute. Through comprehensive assessment, its performance conforms to the provisions of GB1985-89 AC High Voltage Disconnectors and Earthing Switches. It is applicable to the 40.5kV AC 50Hz power system.
Contact Now
The JN2-40.5 indoor high-voltage grounding switch is an indoor high-voltage electrical appliance designed in accordance with the relevant grounding switches in GB1985-89 AC High Voltage Disconnectors and Grounding Switches, which is equivalent to IEC129-84 Disconnectors and Grounding Switches and IEC694-84 Common Terms for High Voltage Switchgear and Control Equipment.JN2-40.5 grounding switch is applicable to 35KV and below three-phase AC 50HZ power system, and has voltage monitoring device.
Contact Now
Suspension tempered glass insulator products are used for insulating and suspending wires in high-voltage and ultra-high-voltage AC and DC transmission lines.Type of insulator acc. RussianstandardUltimateMechanical Strength of insulators, KN, not lessDiameter of glass shed (D), mmSpacing, mmCreepagedistance, mmWeight, kgVoltage withstand, kV, not lessImpulseFrequency50 Hz, wetRadio interference levelU40BSU40BL401751001101851,7703025
Contact Now
Conductive partThe fixed contact is composed of a copper plate bent into a right angle, and the perforated end of the fixed contact can be connected with the bus through a screw; The other end is short, and it contacts the moving blade (moving contact) when closing.Two copper plates form a contact strip, also known as a moving contact, which can rotate around the shaft for a certain angle. When closing, it holds the static contact. There is a clamping spring between the two copper plates to adjust the contact pressure between the dynamic and static contacts.
Contact Now
Features of arrester with series gap □ Product model description1. Under normal conditions, the series gap of the arrester isolates the arrester from the system, and the arrester does not participate in the operation, thus prolonging its service life;2. For the system with frequent voltage fluctuation, the gap can be broken down to make the arrester work only when the voltage exceeds the specified value, avoiding the frequent action of the gapless arrester;3.
Contact Now
Reference standardsGB11032-2000 AC gapless metal oxide arresterJB/T8952-2005 Metal Oxide Surge Arrester with Composite Jacket for AC SystemJB/T10497-2005 Metal Oxide Surge Arresters with Series Gap and Composite Jacket for AC Transmission LinesGB311.11-1997 Insulation Coordination of High Voltage Transmission and Transformation EquipmentJB/T8459-2006 Preparation Method of Arrester Product Model□ Structural characteristics1.
Contact Now
□ Technical standards The standard for product production is GB11032-2000 (eqvIE60099-4.1991) "AC gapless metal oxide arrester", JB/8952-20045 "composite metallization arrester for AC system with no gap in the jacket"□ Product model description □ Conditions of useYH |---- Composite jacket metal oxide arrester (HY is the old model) | Y is metal oxide surge arrester with porcelain jacket5 |---- Nominal discharge current KaW |---- Structural features W: No gap C: Series gap R: Parallel gapS |---- place of use S: Power distribution Z: Power
Contact Now
Drop type (drop type, detachable type) lightning arrester is a distribution type zinc oxide lightning arrester that is modified and skillfully installed on the drop type mechanism of the drop type fuse, so that the lightning arrester can be easily detected, repaired and replaced with the help of an insulating switch lever under the condition of continuous power supply, which not only ensures the smoothness of the line, but also greatly reduces the work intensity and time of power maintenance personnel, It is especially suitable for places that are not suitable for power failure, such as post a
Contact Now
Distribution ArresterProduct use conditions:a) Suitable for indoor and outdoor use;b) Ambient temperature -40°C~+40°C;c) The altitude does not exceed 3000m (the porcelain sleeve type does not exceed 1000m);d) The power frequency is not less than 48Hz and not more than 62 Hz;e) The long-term power frequency voltage applied between the arrester terminals does not exceed the continuous operating voltage of the arrester;f) Areas with an earthquake intensity of 8 degrees or below;g) The maximum wind speed shall not exceed 35m/s. Product Model Description:According to JB/T 8459-1996 "Surge
Contact Now
The discharge counter for lightning arrester is a high-voltage electrical apparatus used to monitor the discharge action of lightning arrester. Its structure consists of nonlinear resistance, electromagnetic counter and some electronic components. Under normal operating voltage, the leakage current flowing through the counter is very small, and the counter does not act.
Contact Now
1. Reasonable design, novel structure, reliable technical performance, compact shape, light weight, flexible installation, high tensile strength, collision resistance, and no damage during transportation;2. The advantages of silicon rubber sheathed metal oxide arrester are cited.
Contact Now
GW9-10 outdoor high-voltage disconnector is a single-phase AC 50HZ high-voltage switchgear, which is used in the power system with the rated voltage of 10KV to connect or disconnect the power supply with voltage and without load.The disconnector is operated with insulating rod.□ Operating environmenta. Altitude not exceeding 1000mb. Ambient air temperature: upper limit+40 ° C, lower limit - 30 ° C in general areas, and - 40 ° C in alpine areasc. Wind pressure shall not exceed 700Pa (equivalent to wind speed of 34m/s)D. Seismic intensity shall not exceed 8 degreesE.
Contact Now