LXQ (LXQ3, LXQ4) type nonlinear resistance harmonic eliminator (harmonic eliminator for short) for neutral point of voltage transformer is installed in primary winding (or secondary winding) Y of 6~35kV voltage transformer (PT for short). A nonlinear resistance harmonic damping device between the neutral point of the junction line and the ground. Compared with the traditional RXQ type harmonic eliminator, the LXQ type harmonic eliminator has been greatly improved in design to improve the thermal capacity of the harmonic eliminator. The harmonic eliminator has superior electrical performance.
Contact Now
This unit has been specifically designed to meet the needs of contractors where the necessiiy or the ability to have a Cable Drum Trailer is simply not practical.Available with either a fixed spindle (shown), i.e. drum loaded by external means, or supplied self sufficient in lifting and lowering as used on standard Cable Drum Trailers in our range.The unit comes with a range of options to suit most applications for both the Utility and Rail industries.Diesel, Petrol, Electric or PTO Drum Drive system for ease of cable payout, unit can be pendant controlled.
Contact Now
The overall structure of this product adopts a three-phase common box type, the bushing enters and exits the line, the box is filled with dry air, and the electric spring fan operating mechanism is arranged on the side of the box, which can be used reliably under severe environmental conditions. The vacuum interrupter of this product adopts ceramic shell, cup-shaped longitudinal magnetic field contact structure, copper chromium contact material, and has excellent breaking and closing short-circuit current capacity. The product is small in size, light in
Contact Now
FN12-12 and FN12-12R combined apparatus are three-phase high-voltage switchgear with a rated voltage of 12KV and a rated frequency of 50Hz. They are used for breaking and closing load current, closed-loop current, no-load transformer and cable charging current, closing short circuit current, and load switches equipped with grounding switches.
Contact Now
The role of drop-out fuses10kV equipment can be installed on the high-voltage side of the transformer on the pole, where the transformer and capacitor are connected to the line. The drop-out fuse can effectively protect the circuit from overload and short-circuit. At the same time, it can also be installed at the end of a long line or on a branch line, which can provide extended protection for areas that cannot be protected by relays.
Contact Now
The performance of JN15-12 household air high-voltage grounding switch meets the requirements of GB1985-89 AC High Voltage Disconnectors and Grounding Switches and IEC129, and is applicable to 12kV and below AC 50Hz power systems. It can be used together with various types of high-voltage switch cabinets as grounding protection.Advanced design and reliable technical performance; Simple structure, convenient installation and debugging; Have the ability of quick opening and closing.□ Operating environment1. The altitude shall not exceed 1000m;2.
Contact Now
Low-voltage cable lines are widely used in low-voltage power distribution systems because of their reliable operation, lack of poles, lack of ground occupation, lack of unsightliness, and less influence from the outside world.ApplicationFixed indoor, outdoor and underground installations.StandardsHD 603-5D SI, IEC 60502-1,IEC 60332-1 Cat. B.
Contact Now
The lightning arrester is connected between the cable and the earth, usually in parallel with the protected equipment. The lightning arrester can effectively protect communication equipment. Once abnormal voltage occurs, the lightning arrester will act to protect. When the communication cable or equipment is operating under normal working voltage, the arrester will not work and will be regarded as open circuit to the ground.
Contact Now
Capacitive HY5WR surge arrester is used in 6KV lines to prevent overvoltage generated by vacuum switch and oil-less switch operation capacitor bank, protect capacitor bank from overvoltage damage and absorb overvoltage energy.Advantages of H05WR-10/27 capacitive mine injectorHY5WR-10/27 Capacitor Harm Avoidance Device has good volt-ampere characteristics, excellent protection performance and impact response characteristics, high tolerance to multiple lightning and overvoltage performance, good pollution resistance and other advantages, and the structure Simple, HY5WR-10/27 capacitive arrester
Contact Now
Distribution ArresterProduct use conditions:a) Suitable for indoor and outdoor use;b) Ambient temperature -40°C~+40°C;c) The altitude does not exceed 3000m (the porcelain sleeve type does not exceed 1000m);d) The power frequency is not less than 48Hz and not more than 62 Hz;e) The long-term power frequency voltage applied between the arrester terminals does not exceed the continuous operating voltage of the arrester;f) Areas with an earthquake intensity of 8 degrees or below;g) The maximum wind speed shall not exceed 35m/s. Product Model Description:According to JB/T 8459-1996 "Surge
Contact Now
Three phase combined zinc oxide arrester with composite sheath is a new type of protective appliance used to protect the insulation of power equipment from over-voltage hazards. It effectively limits the over-voltage between phases while limiting the over-voltage between phases and ground. It is widely used to protect vacuum switches, rotating motors, parallel compensation capacitors, power plants, substations, etc. This kind of combined arrester has been used for more than ten years, and the practice has proved that it is a practical and effective measure to limit the interphase overvoltage.
Contact Now
1. Reasonable design, novel structure, reliable technical performance, compact shape, light weight, flexible installation, high tensile strength, collision resistance, and no damage during transportation;2. The advantages of silicon rubber sheathed metal oxide arrester are cited.
Contact Now
The main component of the metal oxide arrester's nonlinear resistance valve is zinc oxide, which has excellent nonlinear characteristics. Under normal operating voltage, the resistance value is very high, which is actually equivalent to an insulator. Under over-voltage, the resistance of the resistor is very small, and the residual voltage is very low. However, under normal operating voltage, the valve plate will deteriorate due to long-term power frequency voltage, which will cause changes in resistance characteristics and increase the leakage current flowing through the valve plate.
Contact Now
Metal Oxide ResistorsThe metal oxide resistor is the core part of the lightning arrester. It uses zinc oxide as the main component, adding a small amount of bismuth oxide, cobalt oxide, chromium oxide, manganese carbonate, antimony oxide and other trace additives, and is sintered at high temperature. The microstructure of metal oxide resistors is mainly composed of zinc oxide grains, grain boundary layer and spinel phase.
Contact Now
Our 110kV and 220kV composite jacket line arresters have passed the type test of the National Insulator Arrester Testing Center and have performed well.Our company has adopted a unique design of core rod through ring resistor, directly crimping end fittings and reliable sealing process to make it have the tensile strength of suspension composite insulator. (Patent No.: 2007200155561.4).
Contact Now
1) It is used to protect electrical equipment from high transient over-voltage and limit the freewheeling time and the freewheeling amplitude.
Contact Now
Composite insulators are composed of three parts: insulating core rod, silicone rod rubber sheath and connecting fittings at both ends. Insulating mandrel is the abbreviation of epoxy resin fiberglass lead rod, it is the skeleton of composite insulator, it plays multiple functions such as supporting umbrella cover, inner insulation, connecting hardware at both ends, and bearing mechanical load, etc.
Contact Now
Suspension tempered glass insulator products are used for insulating and suspending wires in high-voltage and ultra-high-voltage AC and DC transmission lines.Type of insulator acc. RussianstandardUltimateMechanical Strength of insulators, KN, not lessDiameter of glass shed (D), mmSpacing, mmCreepagedistance, mmWeight, kgVoltage withstand, kV, not lessImpulseFrequency50 Hz, wetRadio interference levelU40BSU40BL401751001101851,7703025
Contact Now
For border and coastal defense monitoring and important places, long-distance and ultra long-distance observation equipment is essential. Long focus and multi field of view infrared thermal imager products can well meet the needs of long-distance observation at night. The infrared optical system designed with long focus and multi field of view can not only meet the needs of target search, but also meet the needs of further observation.