The discharge counter for lightning arrester is a high-voltage electrical apparatus used to monitor the discharge action of lightning arrester. Its structure consists of nonlinear resistance, electromagnetic counter and some electronic components. Under normal operating voltage, the leakage current flowing through the counter is very small, and the counter does not act.
Contact Now
Drop type (drop type, detachable type) lightning arrester is a distribution type zinc oxide lightning arrester that is modified and skillfully installed on the drop type mechanism of the drop type fuse, so that the lightning arrester can be easily detected, repaired and replaced with the help of an insulating switch lever under the condition of continuous power supply, which not only ensures the smoothness of the line, but also greatly reduces the work intensity and time of power maintenance personnel, It is especially suitable for places that are not suitable for power failure, such as post a
Contact Now
The lightning arrester is connected between the cable and the earth, usually in parallel with the protected equipment. The lightning arrester can effectively protect communication equipment. Once abnormal voltage occurs, the lightning arrester will act to protect. When the communication cable or equipment is operating under normal working voltage, the arrester will not work and will be regarded as open circuit to the ground.
Contact Now
summaryAs a special accessory of the arrester, the disconnector is used in series with the arrester. The purpose is to use power frequency short circuit current to make the disconnector act when the arrester is abnormal and fails, so that the grounding terminal of the disconnector can be automatically disconnected, and the arrester can be withdrawn from operation to prevent further expansion of the accident.
Contact Now
□ Technical standards The standard for product production is GB11032-2000 (eqvIE60099-4.1991) "AC gapless metal oxide arrester", JB/8952-20045 "composite metallization arrester for AC system with no gap in the jacket"□ Product model description □ Conditions of useYH |---- Composite jacket metal oxide arrester (HY is the old model) | Y is metal oxide surge arrester with porcelain jacket5 |---- Nominal discharge current KaW |---- Structural features W: No gap C: Series gap R: Parallel gapS |---- place of use S: Power distribution Z: Power
Contact Now
Capacitive HY5WR surge arrester is used in 6KV lines to prevent overvoltage generated by vacuum switch and oil-less switch operation capacitor bank, protect capacitor bank from overvoltage damage and absorb overvoltage energy.Advantages of H05WR-10/27 capacitive mine injectorHY5WR-10/27 Capacitor Harm Avoidance Device has good volt-ampere characteristics, excellent protection performance and impact response characteristics, high tolerance to multiple lightning and overvoltage performance, good pollution resistance and other advantages, and the structure Simple, HY5WR-10/27 capacitive arrester
Contact Now
Distribution ArresterProduct use conditions:a) Suitable for indoor and outdoor use;b) Ambient temperature -40°C~+40°C;c) The altitude does not exceed 3000m (the porcelain sleeve type does not exceed 1000m);d) The power frequency is not less than 48Hz and not more than 62 Hz;e) The long-term power frequency voltage applied between the arrester terminals does not exceed the continuous operating voltage of the arrester;f) Areas with an earthquake intensity of 8 degrees or below;g) The maximum wind speed shall not exceed 35m/s. Product Model Description:According to JB/T 8459-1996 "Surge
Contact Now
Three phase combined zinc oxide arrester with composite sheath is a new type of protective appliance used to protect the insulation of power equipment from over-voltage hazards. It effectively limits the over-voltage between phases while limiting the over-voltage between phases and ground. It is widely used to protect vacuum switches, rotating motors, parallel compensation capacitors, power plants, substations, etc. This kind of combined arrester has been used for more than ten years, and the practice has proved that it is a practical and effective measure to limit the interphase overvoltage.
Contact Now
Reference standardsGB11032-2000 AC gapless metal oxide arresterJB/T8952-2005 Metal Oxide Surge Arrester with Composite Jacket for AC SystemJB/T10497-2005 Metal Oxide Surge Arresters with Series Gap and Composite Jacket for AC Transmission LinesGB311.11-1997 Insulation Coordination of High Voltage Transmission and Transformation EquipmentJB/T8459-2006 Preparation Method of Arrester Product Model□ Structural characteristics1.
Contact Now
Features of arrester with series gap □ Product model description1. Under normal conditions, the series gap of the arrester isolates the arrester from the system, and the arrester does not participate in the operation, thus prolonging its service life;2. For the system with frequent voltage fluctuation, the gap can be broken down to make the arrester work only when the voltage exceeds the specified value, avoiding the frequent action of the gapless arrester;3.
Contact Now
1. Reasonable design, novel structure, reliable technical performance, compact shape, light weight, flexible installation, high tensile strength, collision resistance, and no damage during transportation;2. The advantages of silicon rubber sheathed metal oxide arrester are cited.
Contact Now
Y. F series porcelain clad arrestersummaryThe arrester is the basis for insulation coordination of various electrical equipment (transformer, reactor, capacitor, engine, motor, PT, CT, circuit breaker, contactor, etc.) in the power system.
Contact Now
The main component of the metal oxide arrester's nonlinear resistance valve is zinc oxide, which has excellent nonlinear characteristics. Under normal operating voltage, the resistance value is very high, which is actually equivalent to an insulator. Under over-voltage, the resistance of the resistor is very small, and the residual voltage is very low. However, under normal operating voltage, the valve plate will deteriorate due to long-term power frequency voltage, which will cause changes in resistance characteristics and increase the leakage current flowing through the valve plate.
Contact Now
Metal Oxide ResistorsThe metal oxide resistor is the core part of the lightning arrester. It uses zinc oxide as the main component, adding a small amount of bismuth oxide, cobalt oxide, chromium oxide, manganese carbonate, antimony oxide and other trace additives, and is sintered at high temperature. The microstructure of metal oxide resistors is mainly composed of zinc oxide grains, grain boundary layer and spinel phase.
Contact Now
Our 110kV and 220kV composite jacket line arresters have passed the type test of the National Insulator Arrester Testing Center and have performed well.Our company has adopted a unique design of core rod through ring resistor, directly crimping end fittings and reliable sealing process to make it have the tensile strength of suspension composite insulator. (Patent No.: 2007200155561.4).
Contact Now
Composite sheathed metal zinc oxide arresterThe core working element of the product is made of multi-element metal oxide powder mainly composed of zinc oxide, which has excellent nonlinear volt ampere characteristics, fast steep wave response and large flow capacity. Products with gap adopt self blowing gap and pressure equalizing radiation structure, which reduces the dispersion of discharge and has small impact coefficient.The adoption of composite insulating jacket conforms to the development trend of miniaturization, security and maintenance free of international electric power products.
Contact Now
SpecificationsRated voltage kVCustomized mechanical tensile load KNconnection markStructure height H (mm)Minimum arc distance h (mm)Minimum nominal creepage distance h (mm)Lightning full-wave impulse withstand voltage (peak kV not less thanThe operating impulse withstand voltage (peak value) kV is not less thanPower frequency wet withstand voltage 1minkv (effective value) kV is not less thanFXBW4-10/40104011W340±1519040095-60FXBW4-10/70107016W360±1519049095-60FXBW4-10/1001010016W400±1519049095-60FXBW4-20/40204016W450±15280600170-75FXBW4-20/70207016W470±15280750170-75FXBW4-20/1002010016W500±152
Contact Now
1) It is used to protect electrical equipment from high transient over-voltage and limit the freewheeling time and the freewheeling amplitude.
Contact Now
installation and use 1. The fuse allows horizontal or vertical installation 2. When the data of the melt tube does not match the voltage and rated current of the line, it must not be connected to the line for use. 3.
Contact Now
use environment a. The altitude does not exceed 1000 meters; b. The surrounding air environment has no conductive dust and no corrosive, flammable and explosive gases, etc.; c. Wind pressure does not exceed 100Pa (equivalent to wind speed 34m/S); d. The earthquake intensity does not exceed magnitude 8; e. The annual temperature difference ratio is within ±40°C.
Contact Now
The general low light level gun sight is a sight with high definition, good combination of gun and mirror, strong adaptability, reliability and durability, stable performance, good man-machine efficiency and low cost. It is suitable for short-range accurate shooting at night and can solve the rapid aiming and accurate shooting at 25-100 meters at night. The fixture can be quickly changed to adapt to various gun types.
Contact Now
The day and night gun sight can realize all-weather close-range accurate shooting in the daytime, night and low illumination environment, and can solve the rapid aiming and accurate shooting at night from 25m to 100m.and can solve the rapid aiming and accurate shooting at night from 25m to 100m.night and low illumination environment, The day and night gun sight can realize all-weather close-range accurate shooting in the daytime,
Contact Now
It can diagnose the fault of the thermal imager through the communication port of the thermal imaging system, locate the fault group components conveniently and quickly according to the built-in fault expert database, and greatly improve the maintenance efficiency of the fault thermal imager;Through the self-developed comprehensive performance test algorithm of thermal imager, it is convenient and accurate to test the performance parameters of thermal imager: minimum resolvable temperature difference (MRTD), minimum detectable temperature difference (mdtd), field of view (FOV), zero travel mom
Contact Now