The overall structure of this product adopts a three-phase common box type, the bushing enters and exits the line, the box is filled with dry air, and the electric spring fan operating mechanism is arranged on the side of the box, which can be used reliably under severe environmental conditions. The vacuum interrupter of this product adopts ceramic shell, cup-shaped longitudinal magnetic field contact structure, copper chromium contact material, and has excellent breaking and closing short-circuit current capacity. The product is small in size, light in
Contact Now
The circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body, which can be used as a fixed installation unit or equipped with a special propulsion mechanism to form a handcart unit.Model and meaning This type of product is equipped with a bistable permanent magnet operating mechanism. The mechanism is equipped with a permanent magnet. The permanent magnet provides the holding force to keep the switch in the closed and open state.
Contact Now
The circuit breaker has the characteristics of small size, light weight, anti-condensation, maintenance-free, etc., and can adapt to harsh weather conditions and dirty environments.
Contact Now
FN12-12 and FN12-12R combined apparatus are three-phase high-voltage switchgear with a rated voltage of 12KV and a rated frequency of 50Hz. They are used for breaking and closing load current, closed-loop current, no-load transformer and cable charging current, closing short circuit current, and load switches equipped with grounding switches.
Contact Now
The role of drop-out fuses10kV equipment can be installed on the high-voltage side of the transformer on the pole, where the transformer and capacitor are connected to the line. The drop-out fuse can effectively protect the circuit from overload and short-circuit. At the same time, it can also be installed at the end of a long line or on a branch line, which can provide extended protection for areas that cannot be protected by relays.
Contact Now
It integrates the functions of visible light CCD, laser ranging, GPS / Beidou Positioning second generation, electronic compass and data recording. It has the characteristics of low power consumption, small volume, light weight, compact structure, simple operation and portability to complete the detection, aiming, ranging and positioning of targets.
Contact Now
It is mainly used to break and close the load current, overload current and short-circuit current of the power system. It is suitable for protection and control of substations, industrial and mining enterprises, and urban and rural distribution networks, especially for places with frequent operations and urban automatic distribution networks. This product is matched with the controller, which can meet the requirements of the distribution automation system, and can reliably and effectively complete the traditional recloser function.
Contact Now
summaryAs a special accessory of the arrester, the disconnector is used in series with the arrester. The purpose is to use power frequency short circuit current to make the disconnector act when the arrester is abnormal and fails, so that the grounding terminal of the disconnector can be automatically disconnected, and the arrester can be withdrawn from operation to prevent further expansion of the accident.
Contact Now
The lightning arrester is connected between the cable and the earth, usually in parallel with the protected equipment. The lightning arrester can effectively protect communication equipment. Once abnormal voltage occurs, the lightning arrester will act to protect. When the communication cable or equipment is operating under normal working voltage, the arrester will not work and will be regarded as open circuit to the ground.
Contact Now
Itc-3c adopts the modular design idea. The three optical axes of thermal imager, laser ranging system and CCD camera system are parallel to each other. It can output two analog video signals in the infrared and visible bands of the target and background (the two bands are independent of each other). If necessary, it can range the target according to the overall instruction.
Contact Now
GW4 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
normal use conditionsAmbient air temperature: upper limit +40°C lower limit -25°CAltitude below 2000mRelative humidity: the daily average value is not greater than 95%, the monthly average value is not greater than 90%The surrounding air should be free from obvious pollution such as corrosive or flammable gas, water vapor, etc. No frequent violent vibration
Contact Now
Long focal length: it can provide higher spatial frequency for the system to be tested; Large aperture: provide testing possibility for multi-channel optical system; The target plate and blackbody have high infrared emissivity; The system is equipped with vibration isolation air cushion platform; Electrically controlled target wheel is easy to operate and replace; It can meet the test of large aperture thermal imaging system; It can realize the semi-automatic test of all the main parameters of the thermal imager system; High performance test software system.The parameters of the thermal imager
Contact Now
1. After opening, establish a reliable insulation gap to separate the equipment or lines to be repaired from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment [2].2. Change the circuit according to the operation needs.3. It can be used to open and close the small current in the line, such as the charging current of bushing, bus, connector and short cable, the capacitive current of switch voltage equalizing capacitor, the circulating current during double bus switching and the excitation current of voltage transformer.4.
Contact Now
Fuse selection The selection of the fuse should ensure that the distribution transformer internal or the high and low voltage outlet pipe can be quickly fused when there is a short circuit. In practice, the following principles are often used for selection; if the capacity of the distribution transformer is below 160KV, the fuse should be 2-2% of the rated current of the transformer.
Contact Now
Product OverviewGW1-12G (D) series outdoor high-voltage disconnectors are unipolar high-voltage switchgear. They are used to open and close the circuit when there is voltage or no load in the outdoor 12KV line network. The switches with grounding knives are equipped with CS mouth type manual mechanisms to prevent the misoperation of live grounding wires and grounding wires, "closing", etc.
Contact Now
(H) GW13 type neutral point disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing the neutral point connection of transformer without load. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.□ Structure1. Single pole V-shaped double post rotary structure, with small floor area, mainly consists of base, post insulator, conductive circuit, operating mechanism, etc.2.
Contact Now
The main function Vacuum arc extinguishing is adopted, with strong breaking capacity, long electrical life and mechanical life of 10,000 times; Simple structure, maintenance-free, no long maintenance period; Good insulation performance, strong anti-pollution ability; Equipped with spring or electromagnetic operating mechanism, the mechanical performance is reliable and can be operated frequently; No fire and explosion hazards; built-in current transformer, the accuracy reaches 0.2 level, and can real
Contact Now
(H) GW4 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
(H) GW5 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
Y. F series porcelain clad arrestersummaryThe arrester is the basis for insulation coordination of various electrical equipment (transformer, reactor, capacitor, engine, motor, PT, CT, circuit breaker, contactor, etc.) in the power system.
Contact Now
Type B double tube binocular low light level observation mirror can assist pilots to directly observe the environment and search targets in the night, complete night takeoff and landing, formation flight, visual recognition of landmark landform, heaven and earth line, aerial reconnaissance and recognition, search and recognition of ground targets at low altitude, and cooperate with forward-looking infrared to search.
Contact Now
•Note:1,(DEBI Equivalent background illumination, measured after up to 2 minutes stabilization in the dark with the operational voltage applied.2,Signal to noise ratio : measured in the circle(diameter:0.2), equivalent system frequency.3,On the area of 1mm² .illumination flux 0.05lm,lasting 60 seconds .4,Measured for 0.3ms both parallel and perpendicular to the axis separately with power supply applied, totally for 6 times.
Contact Now
1. The altitude shall not exceed 1000m.2. The ambient temperature shall not be higher than+40 ℃ and not lower than - 10 ℃.3. The daily average relative humidity is not more than 95%, and the monthly average is not more than 90%.4. The seismic intensity shall not exceed 8 degrees.5. The installation site shall be free of gas, steam, chemical precipitation, smoke, dust, dirt and explosive corrosive substances that seriously affect the insulation and conductivity of the grounding switch.6.
Contact Now