GW4 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
LXQ (LXQ3, LXQ4) type nonlinear resistance harmonic eliminator (harmonic eliminator for short) for neutral point of voltage transformer is installed in primary winding (or secondary winding) Y of 6~35kV voltage transformer (PT for short). A nonlinear resistance harmonic damping device between the neutral point of the junction line and the ground. Compared with the traditional RXQ type harmonic eliminator, the LXQ type harmonic eliminator has been greatly improved in design to improve the thermal capacity of the harmonic eliminator. The harmonic eliminator has superior electrical performance.
Contact Now
•Note:1,(DEBI Equivalent background illumination, measured after up to 2 minutes stabilization in the dark with the operational voltage applied.2,Signal to noise ratio : measured in the circle(diameter:0.2), equivalent system frequency.3,On the area of 1mm² .illumination flux 0.05lm,lasting 60 seconds .4,Measured for 0.3ms both parallel and perpendicular to the axis separately with power supply applied, totally for 6 times.
Contact Now
SpecificationsRated voltage kVCustomized mechanical tensile load KNconnection markStructure height H (mm)Minimum arc distance h (mm)Minimum nominal creepage distance h (mm)Lightning full-wave impulse withstand voltage (peak kV not less thanThe operating impulse withstand voltage (peak value) kV is not less thanPower frequency wet withstand voltage 1minkv (effective value) kV is not less thanFXBW4-10/40104011W340±1519040095-60FXBW4-10/70107016W360±1519049095-60FXBW4-10/1001010016W400±1519049095-60FXBW4-20/40204016W450±15280600170-75FXBW4-20/70207016W470±15280750170-75FXBW4-20/1002010016W500±152
Contact Now
Using the existing image intensifier technology, the antimony cesium photocathode UV image intensifier is successfully developed, with UV transparent quartz glass as the input window and double proximity focusing image intensifier. Solar blind UV imaging detection module is an imaging detection product for solar blind UV band based on UV image intensifier manufacturing technology, combined with optical design technology and electronic signal processing technology. It is mainly composed of solar blind UV coupling module, solar blind UV optical module and signal processing module.
Contact Now
Super second generation low light level image intensifiers: NT-3, cnt-4 and dnt-6 have greatly improved in signal-to-noise ratio, transmission and resolution, which makes them have higher spectral response in a wide wavelength range, and can obtain better contrast for various observation scenes, whether in jungle, desert, coast, water surface It has excellent observation effect under any background, such as snow. Dnt-6 image intensifier is equipped with power supply with automatic shutter characteristics, and can automatically adjust the gain.
Contact Now
Metal Oxide ResistorsThe metal oxide resistor is the core part of the lightning arrester. It uses zinc oxide as the main component, adding a small amount of bismuth oxide, cobalt oxide, chromium oxide, manganese carbonate, antimony oxide and other trace additives, and is sintered at high temperature. The microstructure of metal oxide resistors is mainly composed of zinc oxide grains, grain boundary layer and spinel phase.
Contact Now
1. Reasonable design, novel structure, reliable technical performance, compact shape, light weight, flexible installation, high tensile strength, collision resistance, and no damage during transportation;2. The advantages of silicon rubber sheathed metal oxide arrester are cited.
Contact Now
The main component of the metal oxide arrester's nonlinear resistance valve is zinc oxide, which has excellent nonlinear characteristics. Under normal operating voltage, the resistance value is very high, which is actually equivalent to an insulator. Under over-voltage, the resistance of the resistor is very small, and the residual voltage is very low. However, under normal operating voltage, the valve plate will deteriorate due to long-term power frequency voltage, which will cause changes in resistance characteristics and increase the leakage current flowing through the valve plate.
Contact Now
HJDW6 outdoor low-voltage knife switch is a single-phase AC 50HZ low-voltage switchgear, which is used in the power system with rated voltage of 0.5KV to connect or isolate the power supply when there is voltage and no load. The knife switch is operated with insulated hook bar The knife switch is a single-phase structure, and each phase is composed of a word mounting plate, a pillar insulator, a knife switch, a contact, etc. The upper end of the knife switch is provided with a fixed pull ring for opening and closing the insulating hook bar□ Operating environmenta.
Contact Now
(H) GW5 type outdoor high-voltage disconnector is used for three-phase AC 50Hz outdoor high-voltage electrical equipment, which is used for opening and closing of lines under the condition of voltage and no load, and for electrical isolation of electrical equipment such as overhauled high-voltage buses and circuit breakers from live high-voltage lines. It can also be used for opening and closing small capacitive or inductive currents. When the knife switch is in the normal opening position, an insulation distance meeting the safety requirements can be provided.
Contact Now
1) It is used to protect electrical equipment from high transient over-voltage and limit the freewheeling time and the freewheeling amplitude.
Contact Now
The discharge counter for lightning arrester is a high-voltage electrical apparatus used to monitor the discharge action of lightning arrester. Its structure consists of nonlinear resistance, electromagnetic counter and some electronic components. Under normal operating voltage, the leakage current flowing through the counter is very small, and the counter does not act.
Contact Now
installation and use 1. The fuse allows horizontal or vertical installation 2. When the data of the melt tube does not match the voltage and rated current of the line, it must not be connected to the line for use. 3.
Contact Now
The performance of JN15-12 household air high-voltage grounding switch meets the requirements of GB1985-89 AC High Voltage Disconnectors and Grounding Switches and IEC129, and is applicable to 12kV and below AC 50Hz power systems. It can be used together with various types of high-voltage switch cabinets as grounding protection.Advanced design and reliable technical performance; Simple structure, convenient installation and debugging; Have the ability of quick opening and closing.□ Operating environment1. The altitude shall not exceed 1000m;2.
Contact Now
Very popular MW cooled detector in the world market. Can work with C308, C330 or C363 stirling cooler.
Contact Now
Very popular MW cooled detector in the world market. Can work with C308, C330 or C363 stirling cooler.
Contact Now
Our 110kV and 220kV composite jacket line arresters have passed the type test of the National Insulator Arrester Testing Center and have performed well.Our company has adopted a unique design of core rod through ring resistor, directly crimping end fittings and reliable sealing process to make it have the tensile strength of suspension composite insulator. (Patent No.: 2007200155561.4).
Contact Now
Glass Pin Insulator is extremely convenient for transportation and installation; it adopts non-breakthrough type design, no need to measure zero value during operation; reliable structure, no damage to the core bar, and can give full play to its mechanical strength.
Contact Now
The coupling between the glass lead rod and the fixture adopts the most advanced crimping technology, with beautiful appearance, small volume, light weight, not easy to break, bending, high torsional strength, strong explosion-proof, and extremely convenient transportation and installation.Type ofinsulator acc.RussianstandardUltimateMechanicalStrength ofinsulators,KN, not lessDiameterof glassshed (D),mmSpacing,mmCreepagedistance,mmWeight, kgVoltage withstand, kV, not lessImpulseFrequency50 Hz, wetRadiointerference levelSHS-10D12,51301602801,35754040SHS-20G131401904001,71355050
Contact Now
Very popular MW cooled detector in the world market. Can work with C308, C330 or C363 stirling cooler.
Contact Now
Electrified railway is a railway with electric locomotive as the basic traction force. It is composed of electric locomotive and electric power supply system.The power supply of the electrified railway is from the national grid. The high-voltage alternating current from the State Grid is sent to the railway traction substation for the first time of voltage reduction, and then sent to the overhead contact system.
Contact Now