Fuse selection The selection of the fuse should ensure that the distribution transformer internal or the high and low voltage outlet pipe can be quickly fused when there is a short circuit. In practice, the following principles are often used for selection; if the capacity of the distribution transformer is below 160KV, the fuse should be 2-2% of the rated current of the transformer.
Contact Now
The role of drop-out fuses10kV equipment can be installed on the high-voltage side of the transformer on the pole, where the transformer and capacitor are connected to the line. The drop-out fuse can effectively protect the circuit from overload and short-circuit. At the same time, it can also be installed at the end of a long line or on a branch line, which can provide extended protection for areas that cannot be protected by relays.
Contact Now
installation and use 1. The fuse allows horizontal or vertical installation 2. When the data of the melt tube does not match the voltage and rated current of the line, it must not be connected to the line for use. 3.
Contact Now
FN12-12 and FN12-12R combined apparatus are three-phase high-voltage switchgear with a rated voltage of 12KV and a rated frequency of 50Hz. They are used for breaking and closing load current, closed-loop current, no-load transformer and cable charging current, closing short circuit current, and load switches equipped with grounding switches.
Contact Now
1. After opening, establish a reliable insulation gap to separate the equipment or lines to be repaired from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment [2].2. Change the circuit according to the operation needs.3. It can be used to open and close the small current in the line, such as the charging current of bushing, bus, connector and short cable, the capacitive current of switch voltage equalizing capacitor, the circulating current during double bus switching and the excitation current of voltage transformer.4.
Contact Now
It is mainly used to break and close the load current, overload current and short-circuit current of the power system. It is suitable for protection and control of substations, industrial and mining enterprises, and urban and rural distribution networks, especially for places with frequent operations and urban automatic distribution networks. This product is matched with the controller, which can meet the requirements of the distribution automation system, and can reliably and effectively complete the traditional recloser function.
Contact Now
summaryAs a special accessory of the arrester, the disconnector is used in series with the arrester. The purpose is to use power frequency short circuit current to make the disconnector act when the arrester is abnormal and fails, so that the grounding terminal of the disconnector can be automatically disconnected, and the arrester can be withdrawn from operation to prevent further expansion of the accident.
Contact Now
Three phase combined zinc oxide arrester with composite sheath is a new type of protective appliance used to protect the insulation of power equipment from over-voltage hazards. It effectively limits the over-voltage between phases while limiting the over-voltage between phases and ground. It is widely used to protect vacuum switches, rotating motors, parallel compensation capacitors, power plants, substations, etc. This kind of combined arrester has been used for more than ten years, and the practice has proved that it is a practical and effective measure to limit the interphase overvoltage.
Contact Now
The overall structure of this product adopts a three-phase common box type, the bushing enters and exits the line, the box is filled with dry air, and the electric spring fan operating mechanism is arranged on the side of the box, which can be used reliably under severe environmental conditions. The vacuum interrupter of this product adopts ceramic shell, cup-shaped longitudinal magnetic field contact structure, copper chromium contact material, and has excellent breaking and closing short-circuit current capacity. The product is small in size, light in
Contact Now
FGW9-12 high-voltage load disconnector is a high-performance disconnector developed by our company by absorbing foreign advanced technology. It has the advantages of reliable contact, large current carrying capacity, and certain arc protection capability. It is used in the power system with the rated voltage of 10kV to connect and isolate the power supply when there is voltage.
Contact Now
Drop type (drop type, detachable type) lightning arrester is a distribution type zinc oxide lightning arrester that is modified and skillfully installed on the drop type mechanism of the drop type fuse, so that the lightning arrester can be easily detected, repaired and replaced with the help of an insulating switch lever under the condition of continuous power supply, which not only ensures the smoothness of the line, but also greatly reduces the work intensity and time of power maintenance personnel, It is especially suitable for places that are not suitable for power failure, such as post a
Contact Now
The discharge counter for lightning arrester is a high-voltage electrical apparatus used to monitor the discharge action of lightning arrester. Its structure consists of nonlinear resistance, electromagnetic counter and some electronic components. Under normal operating voltage, the leakage current flowing through the counter is very small, and the counter does not act.
Contact Now
ZFN21-12D/630-20, ZFN21-12DR/T125-31.5 high-voltage vacuum load switch and combination apparatus are used in three-phase AC 10KV, 50Hz power distribution system. It has the advantages of compact structure, small volume, light weight, long service life, strong making and breaking capacity, safety and reliability, etc.
Contact Now
The main component of the metal oxide arrester's nonlinear resistance valve is zinc oxide, which has excellent nonlinear characteristics. Under normal operating voltage, the resistance value is very high, which is actually equivalent to an insulator. Under over-voltage, the resistance of the resistor is very small, and the residual voltage is very low. However, under normal operating voltage, the valve plate will deteriorate due to long-term power frequency voltage, which will cause changes in resistance characteristics and increase the leakage current flowing through the valve plate.
Contact Now
Electrified railway is a railway with electric locomotive as the basic traction force. It is composed of electric locomotive and electric power supply system.The power supply of the electrified railway is from the national grid. The high-voltage alternating current from the State Grid is sent to the railway traction substation for the first time of voltage reduction, and then sent to the overhead contact system.
Contact Now
□ Technical standards The standard for product production is GB11032-2000 (eqvIE60099-4.1991) "AC gapless metal oxide arrester", JB/8952-20045 "composite metallization arrester for AC system with no gap in the jacket"□ Product model description □ Conditions of useYH |---- Composite jacket metal oxide arrester (HY is the old model) | Y is metal oxide surge arrester with porcelain jacket5 |---- Nominal discharge current KaW |---- Structural features W: No gap C: Series gap R: Parallel gapS |---- place of use S: Power distribution Z: Power
Contact Now
The main function Vacuum arc extinguishing is adopted, with strong breaking capacity, long electrical life and mechanical life of 10,000 times; Simple structure, maintenance-free, no long maintenance period; Good insulation performance, strong anti-pollution ability; Equipped with spring or electromagnetic operating mechanism, the mechanical performance is reliable and can be operated frequently; No fire and explosion hazards; built-in current transformer, the accuracy reaches 0.2 level, and can real
Contact Now
use environment a. The altitude does not exceed 1000 meters; b. The surrounding air environment has no conductive dust and no corrosive, flammable and explosive gases, etc.; c. Wind pressure does not exceed 100Pa (equivalent to wind speed 34m/S); d. The earthquake intensity does not exceed magnitude 8; e. The annual temperature difference ratio is within ±40°C.
Contact Now
Conductive partThe fixed contact is composed of a copper plate bent into a right angle, and the perforated end of the fixed contact can be connected with the bus through a screw; The other end is short, and it contacts the moving blade (moving contact) when closing.Two copper plates form a contact strip, also known as a moving contact, which can rotate around the shaft for a certain angle. When closing, it holds the static contact. There is a clamping spring between the two copper plates to adjust the contact pressure between the dynamic and static contacts.
Contact Now
High temperature control precision and high resolution; High emissivity; Short temperature stabilization time; Low price; Easy to use or integrate.