The role of drop-out fuses10kV equipment can be installed on the high-voltage side of the transformer on the pole, where the transformer and capacitor are connected to the line. The drop-out fuse can effectively protect the circuit from overload and short-circuit. At the same time, it can also be installed at the end of a long line or on a branch line, which can provide extended protection for areas that cannot be protected by relays.
Contact Now
Fuse selection The selection of the fuse should ensure that the distribution transformer internal or the high and low voltage outlet pipe can be quickly fused when there is a short circuit. In practice, the following principles are often used for selection; if the capacity of the distribution transformer is below 160KV, the fuse should be 2-2% of the rated current of the transformer.
Contact Now
Drop type (drop type, detachable type) lightning arrester is a distribution type zinc oxide lightning arrester that is modified and skillfully installed on the drop type mechanism of the drop type fuse, so that the lightning arrester can be easily detected, repaired and replaced with the help of an insulating switch lever under the condition of continuous power supply, which not only ensures the smoothness of the line, but also greatly reduces the work intensity and time of power maintenance personnel, It is especially suitable for places that are not suitable for power failure, such as post a
Contact Now
Reference standardsGB11032-2000 AC gapless metal oxide arresterJB/T8952-2005 Metal Oxide Surge Arrester with Composite Jacket for AC SystemJB/T10497-2005 Metal Oxide Surge Arresters with Series Gap and Composite Jacket for AC Transmission LinesGB311.11-1997 Insulation Coordination of High Voltage Transmission and Transformation EquipmentJB/T8459-2006 Preparation Method of Arrester Product Model□ Structural characteristics1.
Contact Now
Our 110kV and 220kV composite jacket line arresters have passed the type test of the National Insulator Arrester Testing Center and have performed well.Our company has adopted a unique design of core rod through ring resistor, directly crimping end fittings and reliable sealing process to make it have the tensile strength of suspension composite insulator. (Patent No.: 2007200155561.4).
Contact Now
Composite insulators are composed of three parts: insulating core rod, silicone rod rubber sheath and connecting fittings at both ends. Insulating mandrel is the abbreviation of epoxy resin fiberglass lead rod, it is the skeleton of composite insulator, it plays multiple functions such as supporting umbrella cover, inner insulation, connecting hardware at both ends, and bearing mechanical load, etc.
Contact Now
installation and use 1. The fuse allows horizontal or vertical installation 2. When the data of the melt tube does not match the voltage and rated current of the line, it must not be connected to the line for use. 3.
Contact Now
Composite sheathed metal zinc oxide arresterThe core working element of the product is made of multi-element metal oxide powder mainly composed of zinc oxide, which has excellent nonlinear volt ampere characteristics, fast steep wave response and large flow capacity. Products with gap adopt self blowing gap and pressure equalizing radiation structure, which reduces the dispersion of discharge and has small impact coefficient.The adoption of composite insulating jacket conforms to the development trend of miniaturization, security and maintenance free of international electric power products.
Contact Now
Three phase combined zinc oxide arrester with composite sheath is a new type of protective appliance used to protect the insulation of power equipment from over-voltage hazards. It effectively limits the over-voltage between phases while limiting the over-voltage between phases and ground. It is widely used to protect vacuum switches, rotating motors, parallel compensation capacitors, power plants, substations, etc. This kind of combined arrester has been used for more than ten years, and the practice has proved that it is a practical and effective measure to limit the interphase overvoltage.
Contact Now
FN12-12 and FN12-12R combined apparatus are three-phase high-voltage switchgear with a rated voltage of 12KV and a rated frequency of 50Hz. They are used for breaking and closing load current, closed-loop current, no-load transformer and cable charging current, closing short circuit current, and load switches equipped with grounding switches.
Contact Now
HJDW6 outdoor low-voltage knife switch is a single-phase AC 50HZ low-voltage switchgear, which is used in the power system with rated voltage of 0.5KV to connect or isolate the power supply when there is voltage and no load. The knife switch is operated with insulated hook bar The knife switch is a single-phase structure, and each phase is composed of a word mounting plate, a pillar insulator, a knife switch, a contact, etc. The upper end of the knife switch is provided with a fixed pull ring for opening and closing the insulating hook bar□ Operating environmenta.
Contact Now
□ Technical standards The standard for product production is GB11032-2000 (eqvIE60099-4.1991) "AC gapless metal oxide arrester", JB/8952-20045 "composite metallization arrester for AC system with no gap in the jacket"□ Product model description □ Conditions of useYH |---- Composite jacket metal oxide arrester (HY is the old model) | Y is metal oxide surge arrester with porcelain jacket5 |---- Nominal discharge current KaW |---- Structural features W: No gap C: Series gap R: Parallel gapS |---- place of use S: Power distribution Z: Power
Contact Now
Features of arrester with series gap □ Product model description1. Under normal conditions, the series gap of the arrester isolates the arrester from the system, and the arrester does not participate in the operation, thus prolonging its service life;2. For the system with frequent voltage fluctuation, the gap can be broken down to make the arrester work only when the voltage exceeds the specified value, avoiding the frequent action of the gapless arrester;3.
Contact Now
ZFN21-12D/630-20, ZFN21-12DR/T125-31.5 high-voltage vacuum load switch and combination apparatus are used in three-phase AC 10KV, 50Hz power distribution system. It has the advantages of compact structure, small volume, light weight, long service life, strong making and breaking capacity, safety and reliability, etc.
Contact Now
SpecificationsRated voltage kVCustomized mechanical tensile load KNconnection markStructure height H (mm)Minimum arc distance h (mm)Minimum nominal creepage distance h (mm)Lightning full-wave impulse withstand voltage (peak kV not less thanThe operating impulse withstand voltage (peak value) kV is not less thanPower frequency wet withstand voltage 1minkv (effective value) kV is not less thanFXBW4-10/40104011W340±1519040095-60FXBW4-10/70107016W360±1519049095-60FXBW4-10/1001010016W400±1519049095-60FXBW4-20/40204016W450±15280600170-75FXBW4-20/70207016W470±15280750170-75FXBW4-20/1002010016W500±152
Contact Now
wire galloping has brought immeasurable economic losses and social impacts to our country. The composite interphase spacer is a kind of line that can effectively prevent the galloping of line conductors to keep the line safe, and effectively reduce the space of the transmission corridor. It is listed as a compact high-voltage transmission line 2220kV and below in the guidelines for galloping prevention and control of the State Grid Corporation of China.
Contact Now
use environment a. The altitude does not exceed 1000 meters; b. The surrounding air environment has no conductive dust and no corrosive, flammable and explosive gases, etc.; c. Wind pressure does not exceed 100Pa (equivalent to wind speed 34m/S); d. The earthquake intensity does not exceed magnitude 8; e. The annual temperature difference ratio is within ±40°C.
Contact Now
Itc-3c adopts the modular design idea. The three optical axes of thermal imager, laser ranging system and CCD camera system are parallel to each other. It can output two analog video signals in the infrared and visible bands of the target and background (the two bands are independent of each other). If necessary, it can range the target according to the overall instruction.
Contact Now
It can diagnose the fault of the thermal imager through the communication port of the thermal imaging system, locate the fault group components conveniently and quickly according to the built-in fault expert database, and greatly improve the maintenance efficiency of the fault thermal imager;Through the self-developed comprehensive performance test algorithm of thermal imager, it is convenient and accurate to test the performance parameters of thermal imager: minimum resolvable temperature difference (MRTD), minimum detectable temperature difference (mdtd), field of view (FOV), zero travel mom
Contact Now
X4 UAV miniaturized thermal imager is a small thermal imager specially designed for UAV. It has the characteristics of light weight, small volume, low power consumption, strong environmental adaptability and simple operation. The lens of the product is designed by optical passive heat difference elimination technology. It works in an ultra wide temperature range of - 40 ℃ ~ 55 ℃ without focusing, and can adapt to different areas and indoor and outdoor environments.
Contact Now
Stirling cooler for cooled infrared detectors. Model: C308. Made in China. Model: C308. Made in China. Stirling cooler for cooled infrared detectors. Model: C308. Made in China. Stirling cooler for cooled infrared detectors.
Contact Now
Very good delivery time. Lowest price in the world. Can work with C308, C330 or C363 stirling cooler. Very good reliability. Can work with C308, C330 or C363 stirling cooler. Very good reliability. Very good delivery time. Lowest price in the world. Lowest price in the world. Very good delivery time. Very good reliability. Can work with C308, C330 or C363 stirling cooler.
Contact Now
Very popular MW cooled detector in the world market. Can work with C308, C330 or C363 stirling cooler.
Contact Now