The SEB range of Adjustable Width Cable Drum Trailers are designed to cope with the ever increasing size of Cable Drums, High Voltage cables are being laid underground instead of over headlines.
Contact Now
All of the Cable Trailers described below are equipped with braking and road lighting systems to conform to the relevant European type approval specifications and are designed to travel fully laden at road speeds indicated on all European highways. Our full range of highway cable drum trailers and trailer mounted winches can now be used within all European countries without the need for additional individual country inspectionsand approval.For safe and easy drum handling, all SEB Cable Drum Trailers are fitted with hydraulic hand pump operated Iift/lower systems as standard.
Contact Now
Front discharge detector, power detector, mainboard detector, front discharge tooling cable, power tooling cable, mainboard tooling cable, scanner tooling cable, refrigerator, detector tooling cable, display detector, special tooling cable for thermal sensing head.1.Software version identification and software loading of thermal sensor head of thermal imager;2.Simulation control of thermal sensor head of thermal imager;3.Adjustment of internal parameters of thermal sensor head of thermal imager;4.Fault discrimination of thermal sensor head, display / controller and cable assembly of thermal im
Contact Now
This unit has been specifically designed to meet the needs of contractors where the necessiiy or the ability to have a Cable Drum Trailer is simply not practical.Available with either a fixed spindle (shown), i.e. drum loaded by external means, or supplied self sufficient in lifting and lowering as used on standard Cable Drum Trailers in our range.The unit comes with a range of options to suit most applications for both the Utility and Rail industries.Diesel, Petrol, Electric or PTO Drum Drive system for ease of cable payout, unit can be pendant controlled.
Contact Now
Due to electromagnetic induction, the metal shielding layer (or metal sheath) of long line high-voltage single core power cables generates induced voltage, which leads to aging of insulation and reduction of insulation grade, resulting in reduced cable life. Once the induced voltage exceeds the sheath breakdown voltage, the outer sheath is broken down, forming a multi-point grounding fault of single core cables.
Contact Now
The lightning arrester is connected between the cable and the earth, usually in parallel with the protected equipment. The lightning arrester can effectively protect communication equipment. Once abnormal voltage occurs, the lightning arrester will act to protect. When the communication cable or equipment is operating under normal working voltage, the arrester will not work and will be regarded as open circuit to the ground.
Contact Now
Low-voltage cable lines are widely used in low-voltage power distribution systems because of their reliable operation, lack of poles, lack of ground occupation, lack of unsightliness, and less influence from the outside world.ApplicationFixed indoor, outdoor and underground installations.StandardsHD 603-5D SI, IEC 60502-1,IEC 60332-1 Cat. B.
Contact Now
1. After opening, establish a reliable insulation gap to separate the equipment or lines to be repaired from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment [2].2. Change the circuit according to the operation needs.3. It can be used to open and close the small current in the line, such as the charging current of bushing, bus, connector and short cable, the capacitive current of switch voltage equalizing capacitor, the circulating current during double bus switching and the excitation current of voltage transformer.4.
Contact Now
FN12-12 and FN12-12R combined apparatus are three-phase high-voltage switchgear with a rated voltage of 12KV and a rated frequency of 50Hz. They are used for breaking and closing load current, closed-loop current, no-load transformer and cable charging current, closing short circuit current, and load switches equipped with grounding switches.
Contact Now
A range of Trailer mounted Cable Pulling Winches required for the installation of Power Cables where high
pulling tensions are required.
All of the units are designed with the operator in mind. Simple in operation and robustly engineered, these units
are fitted with heavy duty diesel engines powering hydraulic transmission for smooth controlled pulling, and are
fitted with a console mounted line tension indicator so that at all times the operator has a visual display of the
pulling force applied.
Contact Now
wire galloping has brought immeasurable economic losses and social impacts to our country. The composite interphase spacer is a kind of line that can effectively prevent the galloping of line conductors to keep the line safe, and effectively reduce the space of the transmission corridor. It is listed as a compact high-voltage transmission line 2220kV and below in the guidelines for galloping prevention and control of the State Grid Corporation of China.
Contact Now
It is mainly used for non-contact monitoring of dangerous gas leakage at industrial site. It can also be used for coal mine monitoring, high-voltage power transmission and transformation detection, subway safety monitoring, environmental protection and fire rescue.Types of industrial hazardous gases that can be monitored:Hydrogen sulfide, ammonia, propane, sulfur dioxide, methanol, ethylene, methane, sulfur hexafluoride, dichloromethane, ether.
Contact Now
Glass Pin Insulator is extremely convenient for transportation and installation; it adopts non-breakthrough type design, no need to measure zero value during operation; reliable structure, no damage to the core bar, and can give full play to its mechanical strength.
Contact Now
installation and use 1. The fuse allows horizontal or vertical installation 2. When the data of the melt tube does not match the voltage and rated current of the line, it must not be connected to the line for use. 3.
Contact Now
use environment a. The altitude does not exceed 1000 meters; b. The surrounding air environment has no conductive dust and no corrosive, flammable and explosive gases, etc.; c. Wind pressure does not exceed 100Pa (equivalent to wind speed 34m/S); d. The earthquake intensity does not exceed magnitude 8; e. The annual temperature difference ratio is within ±40°C.
Contact Now
Super second generation low light level image intensifiers: NT-3, cnt-4 and dnt-6 have greatly improved in signal-to-noise ratio, transmission and resolution, which makes them have higher spectral response in a wide wavelength range, and can obtain better contrast for various observation scenes, whether in jungle, desert, coast, water surface It has excellent observation effect under any background, such as snow. Dnt-6 image intensifier is equipped with power supply with automatic shutter characteristics, and can automatically adjust the gain.
Contact Now
It can diagnose the fault of the thermal imager through the communication port of the thermal imaging system, locate the fault group components conveniently and quickly according to the built-in fault expert database, and greatly improve the maintenance efficiency of the fault thermal imager;Through the self-developed comprehensive performance test algorithm of thermal imager, it is convenient and accurate to test the performance parameters of thermal imager: minimum resolvable temperature difference (MRTD), minimum detectable temperature difference (mdtd), field of view (FOV), zero travel mom
Contact Now
Long focal length: it can provide higher spatial frequency for the system to be tested; Large aperture: provide testing possibility for multi-channel optical system; The target plate and blackbody have high infrared emissivity; The system is equipped with vibration isolation air cushion platform; Electrically controlled target wheel is easy to operate and replace; It can meet the test of large aperture thermal imaging system; It can realize the semi-automatic test of all the main parameters of the thermal imager system; High performance test software system.The parameters of the thermal imager
Contact Now
Hand held low light level observation mirror is a portable photoelectric observation mirror. The instrument is used to observe targets at night and under low illumination conditions.
Contact Now